Baldor DRX44244T - 200 HP, 1785RPM, 3 Phase, 60HZ, 447T, TEFC, F1 60HZ Three Phase 200 HP

Save $13,236.00
BaldorSKU: DRX44244T

Price:
Sale price$39,708.00 Regular price$52,944.00
Delivery date to be confirmed on Sales Order
or Call for most up to date lead times. (781) 281-8905

Description

Baldor DRX44244T - 200 HP Explosion Proof Drill Rig Duty Motor

Introducing the Baldor DRX44244T, a robust and reliable 200 HP Explosion Proof Drill Rig Duty Motor designed for demanding industrial applications. With a speed of 1785 RPM and a three-phase power supply at 60Hz, this motor is engineered to deliver exceptional performance and durability.

Key Features:

  • Power: 200 HP
  • Speed: 1785 RPM
  • Phase: 3 Phase
  • Frequency: 60Hz
  • Frame Size: 447T
  • Enclosure: Totally Enclosed Fan Cooled (TEFC)
  • Type: Explosion Proof Drill Rig Duty Motor

The Baldor DRX44244T is ideal for applications requiring high reliability and safety in hazardous environments. Its explosion-proof design ensures optimal performance while minimizing risks, making it a preferred choice for drill rigs and other heavy-duty operations.

At Pump-Stop, we are your trusted source for replacement pumps and parts. If you have questions or need assistance finding the right pump for your application, please call us at (781) 281-8905. We recommend checking your current pump for the exact part number or SKU that matches the Baldor DRX44244T to ensure compatibility. Don’t hesitate to reach out if you need help locating the right item!

UPC 781568910375
Supplier Part Number DRX44244T
Category AC Motors
Subcategory Explosion Proof Drill Rig Duty Motors
Product Family General Industrial
Agency Approvals UL, CSA, CCSAUSEEV
Ambient Temperature 40 °C
Approximate Weight (lbs) 2676.0
Auxillary Box No Auxillary Box
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Catalog Number DRX44244T
Constant Torque Speed Range 6-60
Current @ Voltage 222.000 A @ 460.0 V
Design Code B
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 96.2 %
Enclosure TEFC
Feedback Device NO FEEDBACK
Frame 447T
Frame Material Cast Iron
Frequency 60.00 Hz
Haz Area Class and Group Class I, Group C & D
Haz Area Division Division I
Haz Area Temp Code T3C
Heater Indicator No Heater
High Voltage Full Load Amps 222.0 a
Insulation Class F
Inverter Code Inverter Ready
IP Rating NONE
KVA Code G
Max Speed 3600 rpm
Motor Lead Quantity/Wire Size 6 @ 1/0 AWG
Motor Letter Type Three Phase
Motor Standards NEMA
Motor Type A44120M
Mounting Arrangement F1
Number of Poles 4
Output 200.000 hp
Output @ Frequency 200.000 HP @ 60 HZ
Overall Length 48.47 IN
Phase 3
Power Factor 87
Pulley End Bearing Type Ball
Pulley Face Code Standard
Service Factor 1.15
Shaft Diameter 3.375 IN
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator Shaft Slinger
Speed 1785 rpm
Speed Code Single Speed
Starting Method Direct on line
Synchronous Speed 1,800 rpm
Synchronous Speed @ Frequency 1800 RPM @ 60 HZ
Thermal Device - Bearing None
Thermal Device - Winding Normally Closed Thermostat
Voltage 460 V
Voltage @ Frequency 460.0 V @ 60 HZ

Motor Curves