Grundfos 99159443 - DDE 200-4 | Dosing Pump | Economical | Digital

GrundfosSKU: 99159443

Price:
Sale price$7,747.00
Delivery date to be confirmed on Sales Order
or Call for most up to date lead times. (781) 281-8905

Description

Grundfos — World's Largest Pump Manufacturer · Bjerringbro, Denmark
DDE 200-4 B-PV/T/C-F-31A7A7BG · Digital dosing pumps
DDE 200-4100-240V1-Phase50, 60 HzIP65 / TYPE 4X

The Grundfos 99159443 (DDE 200-4 B-PV/T/C-F-31A7A7BG) is a Digital dosing pumps 100-240V 1-Phase — SMART Digital diaphragm dosing pump with internal brushless motor drive. Economic Digital Dosing even for basic dosing applications (Digital Dosing Essential).. Designed for Process liquids transfer, Cooling, Industrial process water treatment.

Voltage
100-240V
Phase
1-Phase
Frequency
50, 60 Hz
Max Pressure
58.02psi
Max Fluid Temp
122°F
Grundfos
World's largest pump manufacturer — engineering and manufacturing in 17 countries since 1945
Industrial Grade
Built and tested to IEC and NEMA standards
Authorized Distributor
Genuine Grundfos product — full manufacturer warranty coverage
Expert Support
Technical help available — call (781) 281-8905 or chat
gf-sh"
Why This Product

Motor-Driven Diaphragm — Precise and Pulsation-Free

Motor-driven diaphragm mechanism delivers chemically accurate dosing without the pressure variation of solenoid-driven designs. Consistent dose volume at each stroke regardless of back-pressure changes in the dosing line.

Grundfos Smart Digital Interface

DDA/DDC series pumps feature the Grundfos Smart Digital interface — touchscreen control, communication protocols (Profibus, Modbus, GENIbus), and external signal input for analogue control from analyzers and SCADA systems.

Chemical Resistance — PVDF and Stainless Construction

Liquid end components in PVDF (polyvinylidene fluoride), stainless steel, and EPDM/Viton for compatibility across a broad range of chemicals — acids, alkalis, oxidizers, and solvents used in water treatment and process applications.

Auto-Degas Function

Automatic degassing function purges gas bubbles from the pump head before dosing — critical for hypochlorite and other gas-releasing chemicals where air pockets cause dosing inaccuracy and pump damage.

Wide Flow Range with One Pump

Variable stroke frequency and length provide a wide effective flow range from a single pump — one pump covers multiple dosing rate requirements without requiring different pump models.

Leak Detection and Dry-Run Protection

Integrated leak detection and dry-run protection prevent chemical spills and pump damage from empty chemical containers — important safety features for unattended dosing installations.

Model Code Decoded — DDE 200-4 B-PV/T/C-F-31A7A7BG
Series: DDE 200-4
Model Code: DDE 200-4 B-PV/T/C-F-31A7A7BG
Performance
Max Operating Pressure 58.02psi
Max Fluid Temperature 122°F
Max Ambient Temperature 113°F
Electrical Specifications
Voltage 100-240V
Phase 1-Phase
Frequency 50, 60 Hz
Protection Class (IP) IP65 / TYPE 4X
Cable / Plug Type US plug
Connections
Materials
Dosing Head Material PVDF (Polyvinylidene fluoride)
Product Identity
Model Number 99159443
Product Series DDE 200-4
Model Code DDE 200-4 B-PV/T/C-F-31A7A7BG
Approvals / Certifications CE, CSA-US, NSF61, RCM
Applications
Process liquids transfer
Cooling
Industrial process water treatment
Important Notices
Electrical Requires correctly rated supply — 100-240V, 1-Phase, 50, 60 Hz. Install with correctly rated circuit protection and motor starter.
Temperature limits Do not exceed max fluid temperature 122°F or max ambient temperature 113°F. Operating outside these limits will damage seals and motor insulation.
Dry running Do not run dry. DDE 200-4 pumps use the pumped fluid to lubricate the shaft seal — dry running destroys the seal within seconds. Install dry-run protection on all automatic installations.
Maintenance Refer to the Grundfos Installation and Operating Manual (IOM) for correct installation, commissioning, and maintenance intervals. Contact PumpStop for documentation.
Documentation
✓ Installation and Operating Manual (IOM) — DDE 200-4
✓ Product Data Sheet — DDE 200-4 B-PV/T/C-F-31A7A7BG
✓ Service Manual and Spare Parts List
Need the IOM, data sheet, or spare parts list? Contact PumpStop and we'll send it over.
Before You OrderConfirm model code, voltage, phase, and frequency match your installation requirements. For sizing help or spare parts guidance, chat or call (781) 281-8905.
EAN 5712607842314
Applications Dosing & Disinfection
Approvals CE
Control panel FRONT-MOUNTED
Control variant B
Density 62.29 lb/ft³
Enclosure class (IEC 34-5) IP65 / NEMA 4X
Gasket PTFE
Gross weight 17.6 lb
Inrush current 70A at 240V (35A/100V) for 2ms
Length of cable 1.5 m
Liquid temperature range 32 .. 122 °F
Mains frequency 50 / 60 Hz
Material Pricing Group 69
Max. Flow 200 l/h
Maximum operating pressure 4 bar
Maximum power input - P1 62 W
Min flow 250 ml/h
Net weight 15.4 lb
Power 1 62 W
Power input - P1 62 W
Product family DDE
Pump inlet Conn. Threaded 3/4#NPTM CodeA7
Pump outlet Conn. Threaded 3/4#NPTM CodeA7
Pumped liquid Water
Range of ambient temperature 32 .. 113 °F
Rated voltage 1 x 100-240 V
Real Time Delivery date to be confirmed on Sales Order  Update with real time availability and Net price
Selected liquid temperature 68 °F
Turn-down ratio 0.5972222222222222
Type No installation set
Type key DDE 200-4 B-PV/T/C-F-31A7A7BG
Type of cable plug USA
Valve ball Ceramic
Valve type Standard

Motor Curves

Dimensional Drawing

Recently viewed

Similar Products