AMT Pumps

AMT Pump Kit Model Reference 4222-95 (4222-K5)

This item ships free!
AMTSKU: 4222-K5

Price:
Price$418.56

or Call for most up to date lead times. (781) 281-8905

Description

AMT Pump Company — A Gorman-Rupp Company · Royersford, PA
Model 4222-K5 · 2˝ Engine Driven AG/Dewatering Pumps · Engine Driven and Diaphragm Pumps
UL/CSA ListedQSP — Quick Ship

The AMT 4222-K5 pump kit model reference 4222-95. Self-primes to 20 Ft. without a foot valve. AMT due to availability of materials and all other causes beyond AMT’s VIP SHIPMENT: Select AMT and IPT branded pumps are available for next day shipment for non-QSP (Quick Ship Products) items and subjected to a specific model surcharge per unit not

Series
2˝ Engine Driven A
Series
2˝ Engine Driven A
Series
2˝ Engine Driven A
QSP — Quick Ship
Ships within 24 hours on standard configurations — no extended lead time
UL / CSA Listed
Listed for safe installation in US and Canadian electrical systems
NEMA 56J Frame
Standard NEMA frame — direct motor replacement with any off-the-shelf motor
Expert Support
Technical specialists available — call (781) 281-8905 or chat
Why This Product

Engine-Driven — Operates Without Utility Power

Engine-driven design provides pumping capacity at remote construction sites, emergency dewatering locations, and any application where utility power is unavailable or unreliable. Honda and Robin/Subaru engines provide proven reliability.

Trash Pump Design — Handles Large Solids

Large volute clearances and semi-open impeller pass rocks, sticks, leaves, and semi-solids that would destroy a standard centrifugal pump. Designed for construction site dewatering where the pumped fluid contains significant debris.

Self-Priming — Fast Deployment

Self-priming capability allows rapid deployment without suction line preparation. Fill the priming chamber once and the pump primes itself — critical for emergency dewatering where every minute of setup time has operational cost.

Cast Iron Construction — Field Durability

Cast iron volute and impeller withstand the abuse of construction site operation. Designed to be serviceable in the field — standard replacement impellers, mechanical seals, and wear rings are stocked by AMT distributors.

High Volume Capability

Engine-driven trash pumps deliver high flow rates at low head — the correct performance curve for fast-fill, fast-drain, and high-volume dewatering applications where moving large volumes quickly is the priority.

Portable Design

Compact, portable design with lifting handle for single-person transport. Engine and pump are close-coupled on a single base — no alignment required after transport or repositioning on the job site.

Technical Specifications
Model Number 4222-K5
Series 2˝ Engine Driven AG/Dewatering Pumps
Category Engine Driven and Diaphragm Pumps
Max Temperature 130° F
Self-Prime Lift 20 Ft.
Key Features
Cast Iron or Thermoplastic
Buna-N, EPDM or Viton®
Optional Seals Available
2˝ NPT Port Size
Self-Priming up to 20 Ft.
Semi-Open, Clog Resistant
Solids Handling and
Engine Options: Honda or CRX
Carry Handle Included
Heavy Duty Steel Base Installed
Built-in Check Valve
(2) NPT Pipe Nipples
Buna-N or Viton® Mechanical Seal, Depending
Built-in Check Valves
Fiber Gasket Casing Seal
Self-primes to 20 feet
Semi-open, Clog Resistant Impeller
Engine Shaft Protected with Stainless Steel
Buna-N or EPDM Mechanical Seal
O-ring Casing Seal
Performance Summary
Self-Priming Lift 20 Ft.
Max Fluid Temperature 130° F
All Models — 2˝ Engine Driven AG/Dewatering Pumps
Model HP Type Frame Voltage Phase Casing Seal Weight List Price
4226-95 5 HP Cast Iron Buna-N 1,650.00
4229-95 6 HP Cast Iron Buna-N 1,094.00
382H-99 5 HP Thermoplastic Buna-N 1,348.00

★ Highlighted = this product (4222-K5). All models share the same casing and spare parts. QSP = ships within 24 hours.

Important Notices
Fluid compatibility For use with non-flammable, non-abrasive liquids compatible with pump component materials. Verify chemical compatibility before use.
Seal compatibility Always verify seal material compatibility with your specific fluid and chemical conditions.
Electrical Requires a properly sized, grounded branch circuit. Do not use an extension cord. Protect motor with a properly sized thermal overload relay.
Temperature limit Maximum fluid temperature 130° F. Exceeding this limit will damage seals and motor insulation.
Available Documentation
✓ Spec Sheet — 2˝ Engine Driven AG/Dewatering Pumps Series
✓ Repair Parts Manual — Specifications Information and Repair Parts Manual 422 Serie
✓ Price Sheet — Current list pricing
Need the spec sheet, repair manual, or price sheet? Contact PumpStop and we'll send it over.
Before You OrderConfirm voltage, phase, and enclosure type are correct for your installation. All models in the 2˝ Engine Driven AG/Dewatering Pumps series share the same casing and impeller — only the motor configuration differs. For configuration guidance, chat or call (781) 281-8905. List pricing shown — contact PumpStop for distributor pricing.

You may also like

Recently viewed