AMT Sewage / Trash Pump 394H-95 3" NPT (394H-95)

This item ships free!
AMTSKU: 394H-95

Price:
Sale price$2,899.18
or Call for most up to date lead times. (781) 281-8905

Description

AMT Pump Company — A Gorman-Rupp Company · Royersford, PA
Model 394H-95 · 2″ to 4″ Sewage Trash Pumps · Self-Priming Electric Pumps
UL/CSA ListedQSP — Quick ShipSelf-Priming

The AMT 394H-95 sewage / trash pump 394h-95 3" npt. The precision lapped faces on the mechanical seal are easily damaged. Handle your replacement seal carefully.

Series
2″ to 4″ Sewage Tr
Series
2″ to 4″ Sewage Tr
Series
2″ to 4″ Sewage Tr
QSP — Quick Ship
Ships within 24 hours on standard configurations — no extended lead time
UL / CSA Listed
Listed for safe installation in US and Canadian electrical systems
NEMA 56J Frame
Standard NEMA frame — direct motor replacement with any off-the-shelf motor
Expert Support
Technical specialists available — call (781) 281-8905 or chat
Why This Product

Self-Priming to 20 Feet — No Foot Valve Required

Built-in check valve enables consistent self-priming to 20 feet of dry suction lift. No foot valve, no external priming pump, no manual flooding of suction line required. Re-primes automatically after momentary loss of prime.

Pull-From-Rear Design — Service Without Disturbing Piping

The pump casing pulls from the rear of the motor without disconnecting suction or discharge piping. Seal replacement, impeller inspection, and cleanout are all accessible from the motor face — significant labor savings on installed pumps.

TEFC Motor — Continuous Industrial Duty

Totally Enclosed Fan Cooled motor prevents moisture, dust, and contaminants from entering the windings. Rated for continuous duty. NEMA 56J frame allows direct replacement with standard off-the-shelf motors from any supplier.

Stainless Steel Motor Shaft — Corrosion-Resistant Seal Interface

303 stainless steel shaft at the seal interface prevents corrosion-driven seal failure — the most common failure mode in chemical transfer pumps. Cast iron shafts corrode at the seal face over time, eventually preventing proper mechanical seal contact.

Dual Volute Casing — Reduced Radial Bearing Load

Dual volute design balances hydraulic forces on the impeller radially. Single-volute designs create a net radial force that accelerates bearing and seal wear at off-BEP operating points. The dual volute extends service intervals on continuous duty applications.

Chemical Compatibility to Specific Gravity 1.3

EPDM/EPR seals handle dilute acids, alkalis, and water-treatment chemicals with specific gravities up to 1.3. The cast iron casing and seal selection make this pump suitable for chemical transfer where standard Buna-N construction would be inadequate.

Technical Specifications
Model Number 394H-95
Series 2″ to 4″ Sewage Trash Pumps
Category Self-Priming Electric Pumps
Max Temperature 180° F
Key Features
Cast Iron Construction
Silicon Carbide/Viton®
2˝, 3˝ & 4˝ NPT Ports Sizes
Maximum Temperature 180° F
Self-Priming to 20 Ft.
Stainless Steel Semi-Open,
Solids Handling and
3˝ & 4˝ Models Feature
Pull-from-Rear Design
Available with 3 to 15 HP
Cast Iron Construction for Abrasive Resistance and Durability
Replaceable Cast Iron Volute/Wearplate Designed for Solids Handling
Silicon Carbide/Viton® Mechanical Seal
Motor Includes Stainless Steel Shaft or Stainless Steel Shaft Sleeve
Built-in Buna-N Check Valve
Available with 3 to 15 HP Totally Enclosed Fan Cooled (TEFC) Electric
Buna-N O-ring Casing Seal Reusable After Clean Out
Single or Three Phase, 3450 RPM Motors
Optional Mounting Base Available for 184/215 JM Frames
Self-Cleaning Stainless Steel Impeller Resists Clogging
Performance Summary
Max Fluid Temperature 180° F
All Models — 2″ to 4″ Sewage Trash Pumps
Model HP Type Frame Voltage Phase Casing Seal Weight List Price
316B-95 3 HP TEFC 56J 230 Cast Iron 1
316A-95 3 HP TEFC 56J 230 Cast Iron 1
393A-95 5 HP TEFC 230 Cast Iron 2

★ Highlighted = this product (394H-95). All models share the same casing and spare parts. QSP = ships within 24 hours.

Important Notices
Fluid compatibility For use with non-flammable, non-abrasive liquids compatible with pump component materials. Verify chemical compatibility before use.
Seal compatibility Always verify seal material compatibility with your specific fluid and chemical conditions.
Electrical Requires a properly sized, grounded branch circuit. Do not use an extension cord. Protect motor with a properly sized thermal overload relay.
Temperature limit Maximum fluid temperature 180° F. Exceeding this limit will damage seals and motor insulation.
Available Documentation
✓ Spec Sheet — 2″ to 4″ Sewage Trash Pumps Series
✓ Repair Parts Manual — 316A-95, 316B-95, 393A-95, 393B-95,
✓ Price Sheet — Current list pricing
Need the spec sheet, repair manual, or price sheet? Contact PumpStop and we'll send it over.
Before You OrderConfirm voltage, phase, and enclosure type are correct for your installation. All models in the 2″ to 4″ Sewage Trash Pumps series share the same casing and impeller — only the motor configuration differs. For configuration guidance, chat or call (781) 281-8905. List pricing shown — contact PumpStop for distributor pricing.
Model 394B-95

Motor Curves

Recently viewed

Similar Products