AMT Pumps

IPT Trash Pump 2" NPT Briggs & Stratton OHV (3930-95)

This item ships free!
AMTSKU: 3930-95

or Call for most up to date lead times. (781) 281-8905

Description

AMT Pump Company — A Gorman-Rupp Company · Royersford, PA
Model 3930-95 · 2″ Cast Iron Trash Pumps · Engine Driven and Diaphragm Pumps
UL/CSA ListedQSP — Quick Ship

The AMT 3930-95 ipt trash pump 2" npt briggs & stratton ohv. Self-primes to 20 Feet without a foot valve. These centrifugal pumps are engine-driven, self-priming (to 20 ft. lift) portable units, shipped completely assembled and mounted. Pumps include a clog resistant, open impeller capable of handling solids as large as 1" diameter for 2" NPT models (up

Series
2″ Cast Iron Trash
Series
2″ Cast Iron Trash
Series
2″ Cast Iron Trash
QSP — Quick Ship
Ships within 24 hours on standard configurations — no extended lead time
UL / CSA Listed
Listed for safe installation in US and Canadian electrical systems
NEMA 56J Frame
Standard NEMA frame — direct motor replacement with any off-the-shelf motor
Expert Support
Technical specialists available — call (781) 281-8905 or chat
Why This Product

Engine-Driven — Operates Without Utility Power

Engine-driven design provides pumping capacity at remote construction sites, emergency dewatering locations, and any application where utility power is unavailable or unreliable. Honda and Robin/Subaru engines provide proven reliability.

Trash Pump Design — Handles Large Solids

Large volute clearances and semi-open impeller pass rocks, sticks, leaves, and semi-solids that would destroy a standard centrifugal pump. Designed for construction site dewatering where the pumped fluid contains significant debris.

Self-Priming — Fast Deployment

Self-priming capability allows rapid deployment without suction line preparation. Fill the priming chamber once and the pump primes itself — critical for emergency dewatering where every minute of setup time has operational cost.

Cast Iron Construction — Field Durability

Cast iron volute and impeller withstand the abuse of construction site operation. Designed to be serviceable in the field — standard replacement impellers, mechanical seals, and wear rings are stocked by AMT distributors.

High Volume Capability

Engine-driven trash pumps deliver high flow rates at low head — the correct performance curve for fast-fill, fast-drain, and high-volume dewatering applications where moving large volumes quickly is the priority.

Portable Design

Compact, portable design with lifting handle for single-person transport. Engine and pump are close-coupled on a single base — no alignment required after transport or repositioning on the job site.

Technical Specifications
Model Number 3930-95
Series 2″ Cast Iron Trash Pumps
Category Engine Driven and Diaphragm Pumps
Max Temperature 180° F
Max Solids Handling 35
Self-Prime Lift 20 Feet
Key Features
Cast Iron Construction
Viton®/Silicon Carbide NORI
2˝ NPT Port Sizes
Self-Priming up to 20 Feet with
Engine Options: Honda
Solids Handling and
Maximum Solids Handling up to ENIGNE
Maximum Head up to 105 Ft.
Maximum Flow up to 185 GPM
Heavy Duty Steel Roll Frame
(2) NPT Pipe Nipples & 2" Street Elbow
Stainless Steel Shaft Sleeve
Maximum Working Pressure 75 PSI
Steel Suction Strainer Included
Heavy Duty Steel Roll Frame Included
Viton®/Silicon Carbide Mechanical Seal
Cast Iron Replaceable Volute/Wearplate
Honda Engines are Overhead Valve
Viton® O-ring and Casing Seal and Impeller (OHV) Designs with Low Oil Alert
Self-primes to 20 Feet with Built-in
Performance Summary
Self-Priming Lift 20 Feet
Max Fluid Temperature 180° F
Max Solids Handling 35
All Models — 2″ Cast Iron Trash Pumps
Model HP Type Frame Voltage Phase Casing Seal Weight List Price
3932-95 5 HP 115 Cast Iron 1

★ Highlighted = this product (3930-95). All models share the same casing and spare parts. QSP = ships within 24 hours.

Important Notices
Fluid compatibility For use with non-flammable, non-abrasive liquids compatible with pump component materials. Verify chemical compatibility before use.
Seal compatibility Always verify seal material compatibility with your specific fluid and chemical conditions.
Electrical Requires a properly sized, grounded branch circuit. Do not use an extension cord. Protect motor with a properly sized thermal overload relay.
Temperature limit Maximum fluid temperature 180° F. Exceeding this limit will damage seals and motor insulation.
Available Documentation
✓ Spec Sheet — 2″ Cast Iron Trash Pumps Series
✓ Repair Parts Manual — [STpyecpifeic taetixotn]s
✓ Price Sheet — Current list pricing
Need the spec sheet, repair manual, or price sheet? Contact PumpStop and we'll send it over.
Before You OrderConfirm voltage, phase, and enclosure type are correct for your installation. All models in the 2″ Cast Iron Trash Pumps series share the same casing and impeller — only the motor configuration differs. For configuration guidance, chat or call (781) 281-8905. List pricing shown — contact PumpStop for distributor pricing.